mirror of
https://github.com/netfun2000/ServerFanSpeedControl.git
synced 2026-02-27 09:53:26 +08:00
Update README_EN.md
This commit is contained in:
78
README_EN.md
78
README_EN.md
@@ -1 +1,79 @@
|
||||
|
||||
# ServerFanSpeedControl
|
||||
Objective: 1U,2U rack server change fan speed
|
||||
|
||||
$\color{#FF3030}{UseByYourOwnRisk!!!}$
|
||||
Basic Information
|
||||
Server:Dell PowerEdge R720
|
||||
iDRAC Version:7
|
||||
Operation System(To manage Server):CentOS 8 / Windows
|
||||
|
||||
1.Enable IPMI Control
|
||||
==================================================================
|
||||
iDRAC 7
|
||||
1.Enter System Setup
|
||||
Use F2 to enter System Setup UI
|
||||

|
||||
2.Enter iDRAC Settings
|
||||

|
||||
3.Set IPMI enabled
|
||||

|
||||
Select Network,Set IPMI become enabled
|
||||

|
||||
|
||||
|
||||
2.Adjust Fan Speed
|
||||
==================================================================
|
||||
CentOS 8 User
|
||||
1.Install IPMI
|
||||
|
||||
|
||||
```
|
||||
yum install epel-release -y
|
||||
yum install ipmitool -y
|
||||
```
|
||||
|
||||
2.Check IPMI is installed
|
||||
```rpm -qa | grep ipmi```
|
||||

|
||||
|
||||
3.Change Fan Speed
|
||||
|
||||
```ipmitool -I lanplus -U ipmiUsername -P ipmiPassword -H ServerAddress raw 0x30 0x30 0x01 0x00```
|
||||
ipmiUsername:Username to login iDRAC,default = root
|
||||
ipmiPassword:Password to login IDRAC,default = calvin
|
||||
ServerAddress: IP of IDRAC address,NOT the operation systemIP or other VMs IP
|
||||
|
||||
0x00 = DISABLE manual operation
|
||||
0x01 ENABLE manual operation
|
||||
|
||||
3.2 Change Spped
|
||||
```
|
||||
ipmitool -I lanplus -U ipmiUsername -P ipmiPassword -H ServerAddress raw 0x30 0x30 0x02 0xff 0x18
|
||||
```
|
||||
|
||||
0xff = Apply to ALL fan
|
||||
0x18 = Percentage of the fan operate,The orginal Fan should be 12000rpm。0x18 is eqaul to 24 in decimal number.
|
||||
|
||||
0xff 0x18 = All Fan will operate in 24% of rpm, you can change 0xff to adjust each fan.
|
||||
|
||||
10% should be suitable for not high load operation (i.e. NAS or HomeAssistant)
|
||||
|
||||
|
||||
|
||||
|
||||
==================================================================
|
||||
Windows User
|
||||
You can use software by @cw1997
|
||||
|
||||
https://github.com/cw1997/dell_fans_controller/releases/
|
||||
|
||||
|
||||
User:IDRAC LoginName,default = root
|
||||
Password:IDRAC password,default = calvin
|
||||
IP: iDRAC server IP,NOT VMs IP
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
Reference in New Issue