# ServerFanSpeedControl
|
||||||
|
Objective: 1U,2U rack server change fan speed
|
||||||
|
|
||||||
|
$\color{#FF3030}{UseByYourOwnRisk!!!}$
|
||||||
|
Basic Information
|
||||||
|
Server:Dell PowerEdge R720
|
||||||
|
iDRAC Version:7
|
||||||
|
Operation System(To manage Server):CentOS 8 / Windows
|
||||||
|
|
||||||
|
1.Enable IPMI Control
|
||||||
|
==================================================================
|
||||||
|
iDRAC 7
|
||||||
|
1.Enter System Setup
|
||||||
|
Use F2 to enter System Setup UI
|
||||||
|

|
||||||
|
2.Enter iDRAC Settings
|
||||||
|

|
||||||
|
3.Set IPMI enabled
|
||||||
|

|
||||||
|
Select Network,Set IPMI become enabled
|
||||||
|

|
||||||
|
|
||||||
|
|
||||||
|
2.Adjust Fan Speed
|
||||||
|
==================================================================
|
||||||
|
CentOS 8 User
|
||||||
|
1.Install IPMI
|
||||||
|
|
||||||
|
|
||||||
|
```
|
||||||
|
yum install epel-release -y
|
||||||
|
yum install ipmitool -y
|
||||||
|
```
|
||||||
|
|
||||||
|
2.Check IPMI is installed
|
||||||
|
```rpm -qa | grep ipmi```
|
||||||
|

|
||||||
|
|
||||||
|
3.Change Fan Speed
|
||||||
|
|
||||||
|
```ipmitool -I lanplus -U ipmiUsername -P ipmiPassword -H ServerAddress raw 0x30 0x30 0x01 0x00```
|
||||||
|
ipmiUsername:Username to login iDRAC,default = root
|
||||||
|
ipmiPassword:Password to login IDRAC,default = calvin
|
||||||
|
ServerAddress: IP of IDRAC address,NOT the operation systemIP or other VMs IP
|
||||||
|
|
||||||
|
0x00 = DISABLE manual operation
|
||||||
|
0x01 ENABLE manual operation
|
||||||
|
|
||||||
|
3.2 Change Spped
|
||||||
|
```
|
||||||
|
ipmitool -I lanplus -U ipmiUsername -P ipmiPassword -H ServerAddress raw 0x30 0x30 0x02 0xff 0x18
|
||||||
|
```
|
||||||
|
|
||||||
|
0xff = Apply to ALL fan
|
||||||
|
0x18 = Percentage of the fan operate,The orginal Fan should be 12000rpm。0x18 is eqaul to 24 in decimal number.
|
||||||
|
|
||||||
|
0xff 0x18 = All Fan will operate in 24% of rpm, you can change 0xff to adjust each fan.
|
||||||
|
|
||||||
|
10% should be suitable for not high load operation (i.e. NAS or HomeAssistant)
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
==================================================================
|
||||||
|
Windows User
|
||||||
|
You can use software by @cw1997
|
||||||
|
|
||||||
|
https://github.com/cw1997/dell_fans_controller/releases/
|
||||||
|
|
||||||
|
|
||||||
|
User:IDRAC LoginName,default = root
|
||||||
|
Password:IDRAC password,default = calvin
|
||||||
|